| Basic Operational System |
Accessories |
| Model TS1-2-E |
Thumb Nail |
Code |
ID# |
Description |
|
Nitrogen Control Group |
|
T1 |
510 |
Pressure Discharge Adapter Set (10) |
|
T1 |
511 |
Nitrogen
Regulator Assy. |
|
T1 |
51104 |
Digital Gauge (0-5c) |
|
T1 |
51105 |
Analog
Gauge (0-6c) |
| |
T1 |
512 |
Cylinder
Support Stand |
| N/A |
T1 |
NCG |
Nitrogen
Control Group (Items: 510, 511, 512) |
| Cartridge
Control Group |
|
T1 |
514 |
Flip
Stand |
| |
T1 |
515 |
Evacuator |
| |
T1 |
516 |
Coupling |
|
Standard Features
- Sealed unit
- Self Cleans
- Auto Stop
- 110v-60Hz
- Capacity 1.8 c/f
- Fill Rate 30 lbs/min
Note: Packaging fee applies to each system
*Latest issue of NFPA 10 requires extinguishers to be stabilized when pressurising
|
N/A |
T1 |
CCG |
Cartridge Control Group (Items: 514, 515, 516) |
| Powder
Control Group |
|
T1 |
530 |
The Extractor
(Fills directly from Pail) |
|
T1 |
531 |
Recovery Unit
(Allows power recovery and storage ) |
|
T1 |
532 |
Sampling Unit
(Allows removal of powder sample from
Extinguisher) |
| |
T1 |
PCG |
Powder
Control Group(Items: 530, 531, 532)
|
|
| Water Pressure Service Stand |
Accessories |
| Model 523 |
Thumb Nail |
Code |
ID# |
Description |
|
|
|
|
Service Head and Safety Cage |
| Pressure Graphics Tracking System |
|
T3 |
552 |
Electronic Control System |
|
W2 |
550 |
Test Label Printer |
| |
W2 |
DK2212 |
Test Label (roll 600") |
|
Standard Features
- Pre-Test level control settings
- Closed circuit operation
- Individual water and air control valves
- Fills to correct level
- Tests cylinders and drains to correct level
- Manual rotation (see through) safety cage
- Fills-tests-dries cylinder in seconds
- A dream to operate
- Uses hand tight quick coupling adapters (order separately)
- For multiple testing, order additional service head w/safety cage (max 4)
Optional Special Features
- Electronic Test Tracking System
- Test Label Printing - Record Keeping - Reporting
- Field and local scanning with downloading features
|
|
| High Pressure Test System |
Accessories |
| Model 551 |
Thumb Nail |
Code |
ID# |
Description |
 |
|
|
|
Test Adapter Set (7) |
|
|
|
Hoist & Trolley Set w/Chain Bucket (500 lbs) |
|
|
512 |
Cylinder Support Stand |
|
|
|
Water Control Basin |
|
Standard Features:
- Control Assembly
- Test Head
- Test Jacket
- Pressure Supply Group
- Electronic Scale
- Calibrated Cylinder (10k)
Optional Features:
- Preset test level control
- Auto-tracking, recording and reporting
|
|
|
|
Cylinder Fill Head |
|
|
|
Gantry Support Assembly
(provides stabilized frame for cylinder movement)
|
|
| Basic Operational Unit |
Accessories |
| Model 544 |
Thumb Nails |
Code |
ID# |
Description |
 |
|
02 |
|
Electronic Scale (5 lbs x 0.1 oz) |
|
03 |
|
High Pressure Regulator |
|
04 |
|
Disc & Bushing Type A (100) |
|
05 |
|
Disc & Bushing Type AA (100) |
|
06 |
|
Adapter CO2 Cylinder |
|
07 |
|
Adapter N2 Cylinder |
|
Standard Features:
- Designed to hold and stabilize the cartridge during recharging
- Use existing charge stems
- Does not use threads
- Has vertical & horizontal holding jaws
- Will handle ALL sizes of cartridges
|
|
|
|
Cylinder Flip Stand
A low cost holding device with multiple positions with Floor Stand. Specifically designed for servicing the Cartridge type Extinguisher. |
|
|
|
|
Evacuator
- For servicing the cartridge type extinguisher
- Supplied with couplings for each size of extinguisher
- Permits the operator to couple transfer line whereby one extinguisher can be emptied to another extinguisher or to the recovery unit or vaccum chamber while screening the powder as it leaves the extinguisher being emptied.
|
|
|
|
|
Sampling Unit
Designed to receive a sample of chemical from an outside source for examination without contaminating the system. The sample may be extracted from a pressurized or cartridge unit. Essential for carrying out annual maintenance on the cartridge extinguisher. |
|
|
|
|
Powder Recovery Unit
Allows the recovery of powder from anywhere utilizing a vacuum principle. It will pull powder from a partially filled extinguisher or from a pail using a screened Wand. Directly coupled to another module it will empty the the contents into a recycled pail for examination, reuse, or disposal. It permits the complete purging of your system should it become contaminated. |
|
|
|
|
Extractor
The Extractor has been designed to transfer chemical directly from the supply pail to the extinguisher or to the vaccu chamber. It has a screened outlet which prohibits the entry of foreign matter or lumps in the recipient container. As seen on the photo, the supply container is deposited on the base of the swivel assembly and locked into position, the cone is lowered onto the rim and locked into position and the device is ready for operation. |
|
|
|
|
Cylinder Vise
- Pneumatic-Belt Type
- Embossed Belting
- Link Chain Holder
- Tool Holder
- Adjustable
|
|
|
|
|
Cylinder Swivel Rack
- Rugged steel construction
- Flip control stabilizer
- Control valve for air & water
- Push rod cylinder stabilizer
- Handles portables through 100 lbs cylinders
- The right product for the right price!
|
|
|
|
|
Cylinder Air Dryer
A cylinder dryer design to use after hydrotesting
- Dries incredibely fast
- Complies with NFPA 10 regulations
- Thermal beraker to avoid overheating
- 110 V
- Hand control on heating
|
|
|
|
|